Browse Categories
Search

Dual Chamber Glove Box (94" x 31" x 36") with Gas Purification System (H2O&O2< 1ppm) and Openable Left Front Window - VGB-6-II-LD


Please email for lead time
Item Number: VGB-6-II-LD
Transported by LTL Freight (Truck)

VGB-6-II-LD is a dual stainless steel glove box designed for researchers in material science, chemistry, semiconductor, and related topics. The purification cylinder is made of BASF antioxidant materials from Germany and UOP water adsorbent materials from the US in order to achieve a low water and oxygen concentration of lower than 1ppm, such that experiments can be conducted in an ultra clean and highly purified gas environment. It is integrated with vapor pressure control system, purity control system, automatic gas purity regeneration control system, auto alarm, and system data log recordingVGB-10-II is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics. 

SPECIFICATIONS
Working Voltage 110VAC or 220VAC, 50/60Hz, Single Phase
Max. Power Consumption 1.7KW
Glove Box Chamber

  • Openable left-front window panel (tempered glass, 8 mm thick)
  • Dimensions: 2400mm(L) x 800mm(W) x 930mm(H)
  • Case Material: Stainless Steel 304
  • 12mm thick double layer laminated safety glass with corrosion protection film for operating in a safe and easy manner.
  • <0.05 Vol% / hr (Depending on oxygen concentration inside the glove box)
  • Built-in fluorescent lamp
  • Two slidable shelves, 300mm L x 250mm W x 300mm H
Airlock Chamber
  • Antechamber Dimensions: 385mm(Dia.) x 588mm(L)
  • Small Chamber Dimensions (for tools): 150mm(Dia.) x 300mm(L)
  • Max. vacuum level: 100 Pa
Attainable purity level
  • Water concentration: <1 ppm (20°C, 1 atm)
  • Oxygen concentration: <1 ppm (20°C, 1 atm)
Working Gas
  • Operating gas: Inert gas such as N2, Ar, He
  • Regenerating gas: Mixture of H2 (5%) and Operating gas

Gas Purification System
  • Auto regeneration process
  • Auto purging function
  • Purification Cylinder: made of BASF antioxidant materials and UOP water adsorbent materials
  • Moisture removal capacity: 1.5KG
  • Oxygen removal capacity: 180L
  • Stainless steel pipe connection
  • Blower: Flow Rate: 90m³/h
Filter System
  • One Organic Solvent Filter System filled with replaceable activated carbon (5.2kg)
  • Two pieces of HEPA filters can eliminate particle size > 0.3μm
Control system

  • Siemens PLC control system with 6" touchscreen display
  • Water concentration: 0 - 1000 ppm @0.1 ppm 
  • Oxygen concentration: 0 - 1000 ppm @0.1 ppm
  • Auto pressure control -25 to 25 mbar @0.1mbar
Feedthroughs
  • Power feedthrough is included.
    • power extension board with 5 outlets, 15A max. 
    • Can be 110VAC or 220VAC depending on the input source
Vacuum Pump

  • 240L/m Heavy Duty Double Stage Rotary Vane Pump for faster gas exhaust
  • Vacuum rate: 7.8 cfm
  • Lowest pressure: 0.4pa
Gloves
  • A pair of NORTH Butyl glove is included
  • protection against toxic materials
  • 8" Dia.x 32" Long
Product Dimensions 3115mm(L) x 830mm(W) x 1830mm(H) (123" x 33" x 72")
Heatable Antechamber (optional)  Heatable Antechamber: 200C max., DN385×588mm (L), extra cost $7699
    
Shipping Dimensions & Weight
2 pallets, 1800 lb total weight     #1: 86"x41"x84"     #2: 86"x41"x83"
Operation Instructions   

Warranty
  • One Year limited warranty with lifetime support
  • Rusting and damage due to improper storage condition or maintenance are not covered by warranty
  • Gloves are consumable items and are not covered under warranty



Application Notes & Warnings
  • The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. 
  • The use of corrosive gasses is prohibited as they will damage the water and oxygen sensors.
  • Regularly perform regeneration to maintain the optimum purification efficiency. 
  • The O2 removing rate is largely dependent on the type of purging gas used. For faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass.
  • Corrosive liquid (such as LiPF6 electrolyte) must be remain sealed in a container inside the glove box. Otherwise, liquid vapor may condense and corrode the steel chamber and purification pipeline
  • The golvebox may connect with tube furnace upon request 
  •     

Related Products

Shopping Cart
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
Mailing Lists
MTI sponsorships:
MTI Sponsors Thermoelectrics Workshop

MTI-UCSD Battery Fabrication Lab


MTI Sponsors the Postdoctoral Awards

Upcoming Shows:
Ceramics Expo May 1 - 3 Cleveland OH Booth 646

AeroMat 2018 May 7 - 10 Orlando FL Booth 1612

233rd ECS Meeting May 13 - 17 Seattle WA Booth 200

Recent Attended Shows:
2018 US-China EVBT Apr 8-10 UCSD San Diego CA

2018 MRS Spring Meeting Exhibit Apr 2 - 6 Phoenix AZ


35th International Annual Battery Seminar & Exhibit Mar 26 - 29 Fort Lauderdale FL


TMS 2018 147th Annual Meeting Exhibition Mar 11 - 15 Phoenix AZ


Click here to see our past conferences

 

Notices
1. Prices listed online are valid for US market and whom pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
2. We may add extra charges for paper order and net30 terms due to extra labor cost.
3. The prices listed are subject to change without notice.