GSL-1700X-S60HG tube furnace is designed for processing material under hydrogen gas up to 1700°C safely. The 60 mm OD processing tube is made of pure alumina, and one hydrogen gas detector is included for cutting off hydrogen gas via a built-in solenoid valve immediately upon detection of hydrogen gas leaks. The furnace can be used with all kinds of inert gasses and oxygen gas as well. The precision temperature controller provides up to 30 programmable segments for the heating profile.  
SPECIFICATIONS
 
Furnace Structure
 
  • Double layer steel casing with air cooling to keep furnace surface temperature lower than 60°C. 
  • High purity fibrous alumina insulation for Max. energy saving.

  • Hydrogen detector and solenoid valve are included for safe operation.

  • The hydrogen gas furnace must be placed under a fume hood. Please click here to view the spec of MTI EQ-FH-36 fume hood.
  • For first time buyer, Safe operation training is required at MTI facility with free of charge.
Power

2.5 KW Max. ( 20A breaker required)

Voltage AC 208-240 Single Phase, 50/60 Hz
Max. Temperature 1700°C  ( < 1 hour )
Continuous Temperature 1600°C
Max. Heating Rate  <= 10°C /min (5C/min is recommended to avoid thermal-shocking the alumina tube)
Processing Tube
  • High purity Al2O3 ceramic, Purity > 99.9%; made in USA.
  • 54 mm (I.D) x 60 mm (O.D) x 790 mm length.
  • Two fibrous ceramic tube blocks are included for blocking heat radiation from inside tube (Ceramic blocks must be fully inserted into the furnace chamber before heating).
  • Quartz blocks (optional) are ideal for cleaner processing environment and higher vacuum efficiency.
  • For 60mm tubes, it is recommended that customers purchase two pairs of tube support to prevent the tube from bending under high temperature (please click on the last picture to order).

                       

Heating Zone length 300 mm (12")
Constant temp. zone 75 mm  (3")   within ± 2°
Temperature controller
 
  • PID automatic control via SCR (Silicon Controlled Rectifier) power control with phase angle fired, current limiting resistor.
  • 30 programmable segments for precise control of heating rate, cooling rate and dwell time.
  • Built-in over temperature alarm and protection allows for operation without an attendant.
  • +/- 1 ºC temperature accuracy.
  • RS485 Communication Port.
  • MET certified 30 programmable segments for precise control of heating rate, cooling rate and dwell time.
  • Built in PID Auto-Tune function with overheating & broken thermocouple protection.
  • Over temperature protection and alarm allows for operation without attendant(s).
  • +/- 1 ºC temperature accuracy.
  • RS485 Communications Port.
    • Advanced Temperature Control (Optional)
    • MTS02-Y Temperature control software kit (for YD518P series controllers) + 15" laptop package is available at the options bar. Click for the detail information about the MTS02-Y software kit. 
    • You may upgrade the temperature controller to the Eurotherm 3504 Temperature Controller which is fully compatible with LabVIEW. This package includes a Eurotherm 3504 programmer, a communication cable (RS485 - USB) and a software CD. Click the pic below to view the full spec of Eurotherm 3504 temperature controller.
  •             
Temperature Accuracy +/ - 1°C
Flanges and Gas Inlet
 
One pair stainless steel vacuum flange are installed on two ends of the tube which allow high vacuum up to 10E-5 torr and 5 PSI positive pressure.
  • One solenoid valve is installed on the left of the flange for Hydrogen gas inlet. It connects with hydrogen detector. Once hydrogen gas leak is detected (10% below hydrogen explode point), gas inlet valve will be shut down immediately.
  • One pressure gauge is installed on the end of the gas inlet. Hydrogen gas pressure must be controlled under 5 PSI, which can be adjusted by a stainless steel needle valve.


Left flange side
Right flange side
solenoid valve
Gas-outlet & Flowmeter 

  • One 16 -160 ml/min floating meter is installed on gas-outlet end for adjusting the gas flow rate.
  • 1/4" Dia stainless steel tube is installed for burning hydrogen gas during gas flowing.
  • One long lighter is included in the standard package for igniting hydrogen gas manually.
  • One 6" long neck flexes safe lighter is included for lighting hydrogen gas.
Hydrogen Detector System
      (included)
  • One Honeywell UL Approved Sensepoint Gas Detector is Integrated into the system.
  • Working Temperature Range:   40ºF to +149ºF (-40ºC to +65ºC)
  • Alarm Point:                            H2 Limited Explosive Line 20% (20% LEL).  Once detecting H2 gas beyond the point, it will shut off the inlet valve to the H2 automatically.
Heating Element
Dimension 400 x 300 x 530 mm (15.7" x 12" x 21")
Net Weight 150Kg
Shipping weight 400 lbs 
Dimension after crafting 48"x 40"x 43"  
Warranty One year limited warranty for electrical and mechanical parts
Laptop, software & WiFi Control (Optional)
  • Brand new laptop with Microsoft Window 10 and Microsoft Office 2013 (30 days free trial) for immediate use.
  • Labview Based Temperature Control System (EQ-MTS01) enables user to edit temperature profile, manage heat-treatment recipe, record and plot data for MTI furnaces.
  • A wireless remote control provides up to 300 meters operating range.
  • Above features are available upon request at an extra cost (up to $1,000). Please contact us for more information.
  • Note: 
    The software is only compatible with MTI’s Yudian Temperature Controller

        

Compliance
  • CE Certified
  • UL / MET / CSA Certification is available upon request, additional charges will apply
  • Temperature controller is MET and CE Certified
  • Transformer is UL Certified
                       
Warning

Click here to learn more about the installation of a gas regulator.

  • The tube furnaces with alumina tube are designed for using under vacuum and low pressure < 0.02 MPa / 0.2 Bar/ 3 PSI 
  • Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation. Click here to learn the installation of a gas regulator.
  • Never heat the furnace while the gas release valve is closed and a positive pressure condition exists within the furnace chamber. The pressure gauge must be used to closely monitor the chamber condition at all times during the heating process; please open the gas release valve immediately once the chamber pressure has reached over 3 PSI to prevent unforeseeable damages.
  • The flow rate for gasses should be limited to < 200 SCCM ( or 200ml/min ).
  • The hydrogen gas furnace must be placed under fume hood Please click here to view the spec of MTI EQ-FH-36 fume hood.
  • For first time buyer, Safe operation training is required at MTI facility with free of charge.
Operation Manual             

Related Products

Shopping Cart
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
Mailing Lists
MTI sponsorships:
MTI Sponsors Thermoelectrics Workshop

MTI-UCSD Battery Fabrication Lab


MTI Sponsors the Postdoctoral Awards

Upcoming Shows:
ICM 2018 July 16-20 San Francisco CA Booth 5

AiMES 2018 Sept 30 - Oct 4 Cancun Mexico

Furnaces North America Oct 8-10 Indianapolis, IN Booth 242

Recent Attended Shows:
ICT 2018 July 1-5 Caen France

AABC 2018 June 4-7 San Diego CA


233rd ECS Meeting May 13 - 17 Seattle WA


Click here to see our past conferences

 

Notices
1. Prices listed online are valid for US market and whom pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
2. We may add extra charges for paper order and net30 terms due to extra labor cost.
3. The prices listed are subject to change without notice.