Gas Independent Automatic Pressure Control Set with Dual Solenoid Valves, 4E-5 - 1E3 Torr - EQ-PCG-2V-UL-LD


In stock
Item Number: EQ-PCG-2V-UL-LD

 EQ-PCG-2V-LD automatic pressure control system is designed for applications that need controlling constant pressure in a closed system with an in-line flow such as Vacuum Tube Furnaces. The Anti-corrosive Digital Vacuum Gauge provides an RS-232 analog output of the pressure signal to pressure control unit which directly controls those two solenoid valves (a feed valve and an exhaust valve).  

  • Only suitable for Mechanical Pumpimproperly usage the EQ-PCG-2V-LD with turbo-pump may permanently damage pump-vane.
  • If you need turbo pump to build a Precision Vacuum Pressure Regulating System, please consider our Motorized Valve and Gauge.

SPECIFICATIONS 
Complete Package includes

Working voltage AC 110~220V





Typical Operation Procedures for Controlling the Pressure of Tube Furnace 
  • Install feed valve (inlet) on one end of tube flange, then connect it with gas supply cylinder.
  • Install exhaust valve (outlet) on the other end of tube flange, then connect it to vacuum pump or gas recovery system
  • Install digital pressure gauge & controller on the tube flange
  • Well connect the Pressure Gauge and two Solenoid Valves to Pressure Control Unit,
  • Power on the system by 110/220 VAC power source.
  • Set pressure low limit and high limit on digital pressure gauge
  • The pressure inside the tube chamber will be kept within the desired range
          





Application Notes
Gas flow-in/out rate can largely affect system pressure control accuracy, the minimum range of pressure control recorded by using the system shown in below is:

         
  • +/- 100 mtorr (<1 torr),
  • +/- 20 torr (1~760 torr),
Please click the picture above to see details of system setup.

Operation Manual

Compliance
  • Vacuum gauge is ETL certified
  • All electric components in control box ( >24V) are UL certified
  • CE certified control box is available with $100 upgrade
Warranty One-year limited warranty with lifetime support
Application 
  • Adjust the SP1 and SP2 parameters of the digital pressure gauge.
  • Here are the tips: Long press to increase the value; Press once, wait for 3 seconds, and then long press to decrease the value; Press ADJ to return to the main menu.
  • Only the rubber needle included in the package is allowed to use for adjusting the set point SP1 and SP2. The warranty does not cover a defect resulting from misuse or negligence of this tool.

Related Products

Shopping Cart
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
Mailing Lists
MTI sponsorships:
MTI Sponsors Thermoelectrics Workshop

MTI-UCSD Battery Fabrication Lab


MTI Sponsors the Postdoctoral Awards

Upcoming Shows:
ICM 2018 July 16-20 San Francisco CA Booth 5

AiMES 2018 Sept 30 - Oct 4 Cancun Mexico

Furnaces North America Oct 8-10 Indianapolis, IN Booth 242

Recent Attended Shows:
ICT 2018 July 1-5 Caen France

AABC 2018 June 4-7 San Diego CA


233rd ECS Meeting May 13 - 17 Seattle WA


Click here to see our past conferences

 

Notices
1. Prices listed online are valid for US market and whom pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
2. We may add extra charges for paper order and net30 terms due to extra labor cost.
3. The prices listed are subject to change without notice.