VGB-6-LD is a stainless steel glove box with the hinged type of front door designed for much easy loading and unloading device into the glove-box. The purification cylinder is made of BASF R3-11 Copper Catalyst and Lindy Molecular Sieve in order to achieve a low water and oxygen concentration of lower than 1 ppm, such that experiments can be conducted in a ultra-clean and highly purified gas environment. It is integrated with vapor pressure control system, purity control system, automatic gas purity regeneration control system, and system data log recording. EQ-VGB-6 is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics. 
NEW!! The VGB-6 glove box system has been upgraded with the hinged type of front window with the main chamber since Dec. 2015. Such feature enables easy transportation for larger size equipment into the glove box.  

SPECIFICATIONS:
Structure             
Working Voltage
  • 110 or 220 VAC switchable, 50/60 Hz, single phase
  • Max power: 1.5 kW 
Glove Box Chamber

  • Case Material: Stainless steel 304 with 3 mm thickness
  • Chamber dimension: 1200 mm L x 740 mm W x 900 mm H
  • Openable front window panel (tempered glass, 8 mm thick)
Chamber Condition
  • Water concentration: <1 ppm (20 °C, 1 atm)
  • Oxygen concentration: <1 ppm (20 °C, 1 atm)
Leak Rate
  • <0.05 vol% / hr (depending on oxygen concentration inside the glove box)
Airlock Chamber
  • Antechamber dimension: 360 mm Dia. x 600 mm L
  • Small chamber dimension (for tools): 150 mm Dia. x 220 mm L
Optional vacuum jar

  • Loading and unloading device from front door is much easier than ever !     Vacuum sealed jar is available for air-sensitive  sampel transporting
Working Gas
  • Operating gas: Inert gas such as N2, Ar, He
  • Regenerating gas: For regenerating both oxygen and H2O remover, use mixture of H2 (5-10%) and operating gas 
Gas Purification System
  • Automated regeneration process
  • Automated water and oxygen removal
  • Purification cylinder: made of BASF R3-11 Copper Catalyst and Lindy Molecular Sieve
  • Pipeline: 304 stainless steel, KF40 and KF25 ports
Ports & Fittings
  • Total three KF40 ports on the back of the glove box
Filter System
  • Inlet and outlet filter can eliminate particle size > 0.3 μm
Pressure Control System
  • Automatic pressure control by PLC for the Glove Box Chamber
    • Pressure range: +/- 12 mbar
  • Manual pressure control is allowed via a foot pedal
Purging System
  • Automatic purging system allows easy operating and reduces gas consumption
Control System
  • Siemens PLC control system with 7" touchscreen display
    • Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
    • Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
    • Pressure: -12 to 12 mbar with an accuracy of 0.01 mbar
    • Records for total hours of operation, total regeneration times, time since last regeneration
Pump

  • 240 L/m heavy duty double stage rotary vane pump for faster gas exhaust
  • Vacuum rate: 240 L/m (8.5 cfm)
Gloves
  • A pair of 9 3/4" butyl glove is included for immediate use
Lighting
  • Built-in fluorescent lamp
Dimension
  • Product Dimension: 2000 mm L x 1000 mm W x 1880 mm H (79" x 40" x 74")
  • See the pictures below for detailed dimensions
                 
Shipping Dimension
  • 86" L x 45" W x 91" H
Shipping Weight
  • 640 kg (1400 lbs)
Compliance
  • UL certified glove box is available upon request with extra cost, please choose model# LAB2000 in the option bar.
Warranty
  • One year limited warranty with lifetime support
  • Rusting and damage due to improper storage condition or maintenance are not covered by warranty
  • Gloves are consumable items and are NOT covered by warranty
  • The oxygen sensor is a consumable component NOT covered by warranty. Please use the videos below for properly 1) Replacing a worn unit and 2) Storing the sensor to ensure maximum longevity when not used
  •     
Operation Instructions
&  Video
                  
            
Application Notes & Warnings

  • The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. 
  • The O2 removing rate is largely dependent on the type of purging gas used. For faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass
  • Regularly perform regeneration to maintain the optimum purification efficiency. 
  • O2 sensor is consumable and its expected life-span is around one year. We supply replacement O2 sensor, please click the underline and just order the sensor.
  • The use of corrosive gases is prohibited as they will damage the water and oxygen sensors!
  • Corrosive liquid (such as LiPF6 electrolyte) must be remain sealed in a container inside the glove box. Otherwise, liquid vapour may condense and corrode the steel chamber and purification pipeline.
  • We can connect various tube furnace with the glove box for processing air sensitive materials as pictures below
  • You may order vacuum transportation jar to deliver air-sensitive sample in or out glove-box
  •          

Related Products

Shopping Cart
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
Mailing Lists
MTI sponsorships:
MTI Sponsors Thermoelectrics Workshop

MTI-UCSD Battery Fabrication Lab


MTI Sponsors the Postdoctoral Awards

Upcoming Shows:
MS&T 2018 Oct 14-18 Columbus OH Booth 513

2018 MRS Fall Meeting and Exhibit Nov 25 - 30 Boston MA Booth 901

APS March Meeting 2019 March 4-8 Boston MA

Recent Attended Shows:
Furnaces North America Oct 8-10 Indianapolis IN

AiMES 2018 Sept 30 - Oct 4 Cancun Mexico


Zhejiang University MSE Visiting August 10th Richmond CA


Click here to see our past conferences

 

Notices
1. Prices listed online are valid for US market and whom pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
2. We may add extra charges for paper order and net30 terms due to extra labor cost.
3. The prices listed are subject to change without notice.