High Pressure and High Vacuum Tube Furance with Optional Alloy Tube ( 900 or 1100°C max heat temp.)
|
Click to enlarge
|
Product Options
| |
|
|
OTF-1200X series high pressure and high vacuum split tube furnaces can be chosen from two kinds of alloy tube, e.g. Stainless steel 310S refractory alloy or Ni based super alloy, which offer a solution of heating treatment under high positive pressure or high vacuum pressure with/without inert gas support to process special compound material. The furnace can be heated up to max. 900°C or 1100°C with optional vessel. The operating positive pressure is from 105 to 800 psi according to different heating temperature.
Features
-
Heating temperature up to max. 900°C or 1100°C , Depended on tube allou
-
Stainless steel or nickel-base super alloy processing tube is included ( please choose from product optional )
- Max pressure up to 800 PSI.depended on tube alloy
- Double layer steel casing with air cooling to keep furnace surface temperature lower than 60°C. High purity fibrous alumina insulation for Max. energy saving.
- PID automatic control with 30 steps programmable. Automatic over-temperature and thermal broken protection.
- Two sets of sealing flanges includ high positive pressure flange and high vacuum flange
- The pressure sensor is installed in the flange. The pressure will be displayed in the pressure controller in the front panel of furnace. The alarm system is built in the pressure controller which allow user to set up the high and low limit point of pressure. When the measuring pressure exceed limit point, the alarm strobe and whistle will be activated for warning.
- The furnace is able to be controlled by a computer. And the software and USB cable are included.
- CE approval
Product gallery (click the pic to enlarge)

|
|
|
|
Temperature controller Demo video here
|
CF-63 flange and copper gasket
|
High pressure & High vacuum CF type flange
|
PC control software
|
|
Notice:
1. The heating temperature must be limited by the certain pressure level due to vessel material strength. Please refer to the specifications.
2. The pressure is increasing while the temperutre is rising during operation. So you need to calculate the pressure changing towards your target temperature and set a safe value of pressure during process.
Specifications
|
OTF-1200X-HVHP-60
|
OTF-1200X-HVHP-80
|
OTF-1200X-II-HVHP-80
|
OTF1200X-60UV
|
Process vessel
|
SS310S Stainless Steel alloy
60mm O.D x 51 mm I.D x 1000 mm L
|
SS310S Stainless Steel alloy
80mm O.D x 72 mm I.D x 1000 mm L
|
SS310S Stainless Steel alloy
80mm O.D x 72 mm I.D x 1000 mm L
|
Nickel based super-alloy
OD 60 x ID 52 x Length 1000 (mm)
|
Working pressure vs. working temperatue
|
750 PSI max at ≤650°C
450 PSI max. at ≤700°C
150 PSI max. at ≤800°C
50 psi Max at ≤900°C
Never heat up above 950°C
|
525 PSI max .at ≤650°C
315 PSI max. at ≤700°C
105 PSI max. at ≤800°C
Never heat up above 950°C
|
525 PSI max .at ≤650°C
315 PSI max. at ≤700°C
105 PSI max. at ≤800°C
Never heat up above 950°C
|
800 PSI max. at ≤800°C
300 PSI max. at ≤1000°C
130 PSI max. at 1100°C
Never heat up above 1200°C
|
| Max. Heating temperature without load
|
950°C
|
950°C
|
950°C
|
1200°C
|
Vacuum
|
1E-2 torr by mechanical pump
5E-6 torr by turbo molecular pump
|
1E-2 torr by mechanical pump
5E-6 torr by turbo molecular pump
|
1E-2 torr by mechanical pump
5E-6 torr by turbo molecular pump
|
1E-2 torr by mechanical pump 5E-6 torr by turbo molecular pump
|
| Working gases
|
Inert gas & Hydrogen
No Oxygen
|
Inert gas & Hydrogen
No Oxygen
|
Inert gas & Hydrogen
No Oxygen
|
Inert gas, hydrogen and oxygen
|
Heating temp.
|
900°C max.
|
800°C max.
|
800°C max.
|
1100°C max.for < 1hr
1000C for continuous
|
Heating rate
|
≤30°C/min
|
≤30°C/min
|
≤30°C/min
|
≤20°C/min
|
Heating element
|
Fe-Cr-Al Alloy doped by Mo
|
Fe-Cr-Al Alloy doped by Mo
|
Fe-Cr-Al Alloy doped by Mo
|
Fe-Cr-Al Alloy doped by Mo
|
Heating zone
|
Total length: 440mm Single zone
Constant temp. zone: 150mm ±1°C
|
Total length: 440mm Single zone
Constant temp. zone: 150mm ±1°C
|
Total length: 200mm for each zone (two zone)
|
Total length: 440mm Single zone
Constant temp. zone: 150mm ±1°C
|
Temp. control
|
PID control method with over-temp protection
Temperature stability: ±1°C
|
PID control method with over-temp protection
Temperature stability: ±1°C
|
PID control method with over-temp protection
Temperature stability: ±1°C
|
PID control method with over-temp protection
Temperature stability: ±1°C
|
Positive pressure sensor
|
installed in high pressure flange
|
installed in high pressure flange
|
installed in high pressure flange
|
installed in high pressure flange
|
PC control
|
Yes
|
Yes
|
Yes
|
Yes
|
Pressure alarm sys
|
Upper limit and lower limit control method
Alarm strob and warning whistle
|
Upper limit and lower limit control method
Alarm strob and warning whistle
|
Upper limit and lower limit control method
Alarm strob and warning whistle
|
Upper limit and lower limit control method
Alarm strob and warning whistle
|
Voltage
|
AC 220V 50/60Hz
|
AC 220V 50/60Hz
|
AC 220V 50/60Hz
|
AC 220V 50/60Hz
|
Power
|
2.5KW
(20A breaker required)
|
2.5KW
(20A breaker required)
|
2.5KW
(20A breaker required)
|
2.5KW
(20A breaker required)
|

|
Standard pacakge content
Optional parts
P/N
|
Name
|
Link
|
| EQ-YTP-550
|
Heavy Duty Rotary Vane Vacuum Pump (7.8 CFM -240 L/m)
|
|
| EQ-PV-HVS2
|
Turbomolecular Vacuum Pump Station (up to 1E-7 mbar)
|
|
|
|
Sale Price: Starting at USD$4,595.00
|
Sale Price: USD$19,995.00
|
|
Sale Price: Call for Pricing and Delivery Time
|
| |
|
| | |
|
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed. | |
| | |
|
|
MS&T 2012, Booth# 536, Oct.9-10, 2012, Pittsburgh, PA, USA
 Nanotech 2012, Booth# 712, June 19-20, 2012, Santa Clara, California
ECS 221st, Booth#208, May 7-9, 2012, Seattle,WA, USA
SVC TechCon2012, Booth# 739, May 1- 2, 2012, Santa Clara, California
|
|
|
|
|

|
|
Notices
1. The price listed on line is valid for US market and who pay by credit card only. There will be extra cost for shipping and handling. The price is different from country to country
2. We may add extra cost for paper order and net 30 term due to extra labor cost
3. The price is subject to change without notice
|
|
|