VGB-4H is a vacuumable glove box with moisture purification system which provides a protective gas environment with humidity level < 2 ppm.  It is an ideal working station for Li-ion battery fabrication processes, such as electrolyte injection & settlement and final sealing of battery casing. It is also suitable for material and chemical researchers to process air sensitive materials and solutions.

SPECIFICATIONS:
Power Requirements
  • Working Voltage: 220 VAC, single phase, 50/60 Hz.
  • Power: 1.5 kW.
  • 110 VAC (request at extra cost).
Glove Box Chamber
 
  • Glove Box: EQ-VGB-4A
  • Dimension: 1120 × 740 × 900 mm (L × W × H).
  • Material: 304 stainless steel (3 mm thickness).
  • Ambient temperature: 15 ~ 25 °C (60 ~ 75 F).
  • Pressure limit: 0.01 ~ 15 psi (0.5 ~ 810 Torr).
  • Access for a pair of Butadyl@ gloves (8’’ long); the diameter of the glove port is 190 mm.
  • The glove ports are covered by clamps and sealing flanges.
  • Built-in outlet (maximum power: 1500 W).
  • Leaking speed: 3 Torr/hour.
Airlock Chamber
    • Dimension: 400 (OD) × 360 (ID) × 435 mm (L).
    • Vacuum limit: > 0.001 psi (0.05 Torr).
    Transparent Front Window
    • Dimension: 1040 × 405 mm (L × W).
    Gauge & Valves
    Airlock chamber:
    • One vacuum gauge on the top of airlock chamber.
    • One 1/2” barbed needle valve and one KF-25 vacuum port built in the air lock chamber.
    Glove box chamber:
    • Two KF-25 ports on the top of the rear panel.
    • Three KF-40 ports on the bottom of the rear panel. One of KF-40 has been connected to the pressure release valve.
    • One KF-40 port on the bottom of the left panel.
    • One KF-40 port on the top of the right panel.
                        
    Purification System
    • Remove moisture  <2 ppm, which is Dew Point < -71.7°C  (<11 ppm H2O is usually needed for Li-Ion battery assembly)  --  click to see Conversion of moisture/humidity
    • Built-in Precision Humidity Analyzer with KF25 Flange (0-999 ppm) (accuracy  +/-0.1 ppm).
    • Large capacity moisture absorber: 1.5 kg.
    • Automatic pressure control system is built in to keep the pressure at a constant level.
    • Regenerable (nitrogen gas required).
    Control Panel
      
    • 6’’ color PLC touch panel.
    • Support Chinese and English.
    • Record total cycle time, regeneration time and single cycle time.
    Vacuum pump
     
    • Heavy duty vacuum pump with filter is included for initial pump down and purging if needed.
    • Stainless steel vacuum bellow and valve are included.
    Gas Requirement
    • Working gas:air, nitrogen, argon.          
    • Regeneration Gas: nitrogen.
    Accessory
    • Foot switch (manually control the pump on/off).
    Shipping Dimensions
    • Glove box chamber and airlock chamber: 2000 × 1000 × 1000 mm (L × W × H).
    • Power supply and purification system: 900 × 600 × 850 mm (L × W × H).
    • Frame: 1200 × 800 × 850mm (L × W × H).
    Warranty
    • One-year limited warranty with lifetime support.
    • MTI is not responsible for rusting and cleaning due to improper storage and maintenance.
    Operation Manual  
    Application Notes
    • Always check the joints, gloves, sealing elements, and pipelines for air-tightness before and during the operation
    • Corrosive gasses are prohibited as they will damage the sensors
    • The inlet and outlet of the Air-lock Chamber must not be opened at the same time to prevent contamination by the external gas
    • By capping the glove ports with the vacuum flange, the glove box can be evacuated by a mechanical pump upto 0.5 torrs before filling inert gas, (moisture can be below 180 ppm and oxygen below 200 ppm). Then you can save at least 1-2 tank of inert gas from purging of each operation
    • Please call or email us to get the price and lead time for multi-pins feedthrough on the glove box if you need to measure the sample inside the chamber, MTI's technician can provide a solution without tolerating the seal (leaking rate less than 3 torr/hour) at an affordable price. Please click the picture below to see our customization: 
    • 16 pins electrical feed through outside the glove box
      (4 pins per one feed through)

      16 pins electrical feed through inside the glove box
      (4 pins per one feed through)

       


    Shipping Weight
    • 550 kg (1200 lbs).

    Related Products

    Shopping Cart
    Your cart is empty.
    Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
    Mailing Lists
    MTI sponsorships:
    MTI Sponsors Thermoelectrics Workshop

    MTI-UCSD Battery Fabrication Lab


    MTI Sponsors the Postdoctoral Awards

    Upcoming Shows:
    AiMES 2018 Sept 30 - Oct 4 Cancun Mexico

    Furnaces North America Oct 8-10 Indianapolis, IN Booth 242

    MS&T 2018 Oct 14-18 Columbus OH Booth 513

    Recent Attended Shows:
    Zhejiang University MSE Visiting August 10th Richmond CA

    ICM 2018 July 16-20 San Francisco CA


    ICT 2018 July 1-5 Caen France


    AABC 2018 June 4-7 San Diego CA

    Click here to see our past conferences

     

    Notices
    1. Prices listed online are valid for US market and whom pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
    2. We may add extra charges for paper order and net30 terms due to extra labor cost.
    3. The prices listed are subject to change without notice.