OTF-1200X-UL furnace is configurated to meet UL/CSA certificate standard. The furnace can adopt a 60, 70, 80 or 100mm O.D quartz tube and a pair of stainless steel vacuum sealing flanges with needle valves & gauge allow heating samples under vacuum or gas flow conditions. The temperature of this tube furnace is controlled by a high precision digital controller which provides 30 programmable segments with +/- 1°C accuracy. The max. working temperature is 1200°C. SPECIFICATIONS:
Furnace Structure

|
- Double layer steel casing with air cooling keeps furnace surface temperature lower than 60°C.
- High purity fibrous alumina insulation for maximum energy saving.
- The special refractory coating on liner and heating element to increase furnace life.
- Split cover with Interlock protection, cut the power if door open during furnace heating process.
|
Voltage and Power |
Input voltage 208 - 240VAC Single Phase, 50/60Hz 3KW, Circuit breaker 20A |
Heating Temperature |
- Fe-Cr-Al Alloy doped by Mo
- Max. heating temperature: 1200°C (N2 or other inert gas must be filled inside the tube to resist deformation)
- Continuously heating temperature: 1100°C
- Heating rate: 20°C /min Ma
- Thermal Couples: K type 220mm (8.7") Length with Ceramic Sheath, please click the link to order spare.
|
Heating Zone |
- Total heating zone length: 440mm (~ 18")
- Constant temperature zone: 150mm (+/1°C)
- Please click the image below to view the temperature distribution at 980°C.
Temperature Distribution |
Temperature Controller
 |
- FA-YD518P-AG temperature controller is included.
- Proportional–integral–derivative control (PID control) and auto-tune function
- 30 segments programmed with ramping, cooling and dwelling steps
- Built-in over-temperature alarm and thermocouple failure alarm
- +/- 1 ºC temperature control accuracy
- Default DB9 PC communication port
- MET Certified
|
Temperature controller (optional)

|
- MTS02-Y Temperature control software kit (for YD518P series controllers) + 15" laptop package is available at the options bar. Click for the detail information about the MTS02-Y software kit.
- You may upgrade the temperature controller to the Eurotherm 3204 Temperature Controller which is fully compatible with LabVIEW. This package includes a Eurotherm 3204 programmer, a communication cable (RS485 - USB) and a software CD. Click the pic below to view the full spec of Eurotherm 3504 temperature controller.
|
Fused Quartz Tube Size |
OTF-1200X-60 60 O.Dx55 I.Dx1000 mm L |
OTF-1200X-70 70 O.Dx65 I.Dx1000 mm L |
OTF-1200X-80 80 O.Dx74 I.Dx1000mm L |
OTF-1200X-100 101 O.Dx92 I.Dx 1000mm L |
Refractory Blocks |
- Two fibrous ceramic tube blocks are included for blocking heat radiation from inside tube. (Ceramic blocks must be fully inserted into the furnace chamber before heating)
- Quartz blocks (optional) are ideal for cleaner processing environment and higher vacuum efficiency.
- You may order flange support to avoid tube rotating ( click Pic below right )
 .jpg)
|
Vacuum Flange
|
- One pair of SS 304 vacuum flange is included
- Left flange:
- one thermal feedthrough (for 1/4O.D sheathed thermocouple)
- one needle valve
- one mechanical vacuum gauge -0.1Mpa to 0.15Mpa
- one barb fitting ( click PiC, below left-2 for detail)
- Right flange:
- one KF-25 vacuum port and one needle valve.
Note: The standard flange for 70mm O.D tube has no KF-25 port or thermocouple feedthrough. Click there to see detail pic.
Optional
- The flange with quartz window is available for in-situ Raman or Mossbauer analysis

|
Vacuum Pressure |
- 10E-2 torr by quality mechanical vacuum pump
- 10E-5 torr by the turbo molecular pump.
- The vacuum pump is optional. Please click here to choose a vacuum pump.

|
Product Dimensions
|
Furnace: 590mm(L) ×380mm(W) × 520mm(H)
|
Net Weight |
40kg |
Shipping Dimensions |
45"(L) x 45"(W) x 42"(H) |
Shipping Weight |
200lbs |
Warranty |
One year limited warranty with lifetime support (Consumable parts such as processing tubes, O-rings are not covered by the warranty, please order replacements at related products below.) |
Laptop, software & WiFi Control(Optional) |
- Brand new laptop with Microsoft Window 10 and Microsoft Office 2013 (30 days free trial) for immediate use.
- Labview Based Temperature Control System (EQ-MTS01) enables user to edit temperature profile, manage heat-treatment recipe, record and plot data for MTI furnaces.
- A wireless remote control provides up to 300 meters operating range.
- Above features are available upon request at an extra cost (up to $1,000). Please contact us for more information.
- Note: The software is only compatible with MTI’s Yudian Temperature Controller

|
Compliance |
CE Certificate UL ready CSA ready Click here to understand the certificate and condition. 
|
Application Notes
 Click here to learn the installation of a gas regulator |
- Tube furnaces with quartz tubes are designed for using under vacuum and low pressure < 0.2 bars / 3 psi / 0.02 MPa. Vacuum pressures may only be safely used up to 1000°CThe flow rate for gasses should be limited to<200 SCCM (or 200ml/min) for reducing thermal shocks to the tube
- Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation. Click here to learn the installation of a gas regulator.
- Heating module is consumable. Please click picture below-right to order a replacement.
- The furnace with Sliding flange is available
 |
Operation Instructions & Video
Click here to learn How to set up quartz/ ceramic tube and vacuum flange for MTI Tube furnace. ( also, click picture left to see demo video ) |
 |
STANDARD PACKAGE:
|
|
|
|
|
|
|
|
Sale Price: Starting at USD$1,999.00
|
|
|
| | |
|
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed. | |
| | |
|
MTI sponsorships: MTI Sponsors Thermoelectrics Workshop
MTI-UCSD Battery Fabrication Lab
MTI-VISTEC Cylindrical Cell Pilot Line
MTI Sponsors the Postdoctoral Awards
Announcement: MTI and Celgard have successfully reached the settlement under court for the litigation on patent and trademark
Upcoming Shows:
|
|