Home Page
1500C Three Zone Split Tube Furnace with Flange & Alumina Tube (80 mm O.D.) - OTF-1500X-III-UL
|
In stock
Item Number: OTF1500XIII
Transported by LTL Freight (Truck)
Personalization
Upgrade to Eurotherm Temp controller( 3 zone)+15" Laptop+ USB Cable
|
OTF-1500X-III- is a split three-zone tube furnace with mullite tube and conventional flange working up to 1500°C. Three 30 segments temperature controllers are installed with S type thermal couples and +/ - 1°C accuracy. It is an excellent furnace for exchanging processing tube for multi-purpose. Note: New safety feature: An interlock system has been integrated into the furnace structure since June.2015SPECIFICATIONS:
Power Input |
9KW |
Working Voltage |
AC220V Single-phase 50/60Hz ( 50 A breaker required) |
Max. Working Temperature |
1500°C 《 1 hours |
Continuously Working Temperature |
1400°C
|
Recommend Heating rate |
5°C/min. |
Processing Tube

|
Tube material: Alumina Tube Size: 80 OD × 74 ID × 1200 L mm Optional tube material: Mullite tube Size: 82 O.D x 73 I.D x 1200mm L
|
Heat Zone Length |
- Three heating zones: 200 mm / each (Included 20 mm spacing)
- Total heating zone length: 600 mm
- Constant Temperature Zone length: 350mm (If set 3 zone at same temperature) +/- 2ºC.
- Accept processing tube up to 100 mm diameter
|
Temp. Profile at 1450ºC
84mm O.D Tube |
(click to enlarge) |
Overall Dimensions |
915 mm × 660 mmW × 762 mmH |
Temperature Controllers
 
|
- PID automatic control with 30 programmable segments for precise control of heating rate, cooling rate and dwell time.
- Built-in overheating & broken thermocouple protection.
- Over-temperature protection and alarm allow for operation without attendant(s).
- +/- 1 ºC temperature accuracy.
- Three S-type thermocouples (one for each zone).
- RS485 Communications Port.
- Optional:
- The furnace may be operated by PC by installing a control module. Please order an MTS-02 control module at extra cost.
- If you order the PC control module together with the furnace, we will install and test it before shipping. We recommend you to order a computer laptop from us to avoid software installation problems. For more information please click here.

|
European Temperature Controllers (optional upgrade)
 |
- 1 heating channel
- 1 program of 8 or 24 segment
- Alarm Relay: Form 'A' and Form ‘C’ built-in
- Digital Communications: RS485
- Temperature Accuracy: ± 0.1ºC
- Recipes: Using a PC tool recipes can be created that can be used to change the operating parameters of the 3000 simply by selecting a new recipe via the HMI. This is very useful where multiple products are processed using the same controller but require different parameters to be set.
|
Laptop, software & WiFi Control(Optional)

|
- Brand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30 days free trial)
- Labview Based Temperature Control System (EQ-MTS01) enables the user to edit temperature profiles, manage heat-treatment recipes, record and plot data for MTI furnaces.
- A wireless remote control provides up to 300 meters of operating range.
- The above features are available upon request at an extra cost (up to $1,000).
|
Vacuum Level |
- 10E-2 torr by quality mechanical vacuum pump
- 10-5 torr by molecular pump
|
Thermal Block Placement |
- Two thermal blacks are included. Please click the picture below to learn how to place them inside tube
- You may order flange support to avoid tube rotating ( click Pic below right )
.jpg) |
Heating Elements & Thermal couples
|
- 24 pcs 1500ºC grade Silicon carbide rod (14mm Dia. x 150mm heating x 413mm length)
- The heating element is consumable, Please click the picture below to order spare and replacement.
- 3 pcs S type thermal couple built-in
|
Net Weight |
160 Kg |
Shipping Weight & Dimensions |
465 lbs; 52" x 40" x 46" |
Application Notes |
- The tube furnaces with mullite tubes are designed for use under vacuum and low pressure < 0.02 Mpa
- Never use graphite crucible and the alumina tube.
- Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation.
- The flow rate for gases should be limited to < 200 SCCM ( or 200ml/min )
- Vacuum pressures may only be safely used up to 1300°C for all mullite tube furnaces:
- Customized long heating zone up to 1200 mm L with 700 mm uniform temperature zone ( +/- 5°C) , and 1800mm mullite tube is available upon request; ( click the picture below to see sketch)
5 zones 6 zones
|
Operation Instructions |
 |
Warranty |
- One year limited warranty with lifetime support (consumable parts such as processing tubes, and O-rings are not covered by the warranty, please order replacements at related products below.).
- ATTENTION: Any damages caused by the use of corrosive and acidic gases are not under the coverage of MTI One Year Limited Warranty.
|
Compliance |
- CE Certified
- NRTL (UL61010) or CSA certification is available upon request at extra cost.
|
|
|
| | |
|
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed. | |
| | |
|
MTI sponsorships: MTI Sponsors Thermoelectrics Workshop
MTI-UCSD Battery Fabrication Lab
MTI-VISTEC Cylindrical Cell Pilot Line
MTI Sponsors the Postdoctoral Awards
Upcoming Shows:
|
|