Browse Categories
Search

1700C Bench-Top Muffle Furnace, (6"x6"x6", 3.6L) with Temperature Controller - KSL-1700X-A1-UL


Transported by LTL Freight (Truck)

Product Options

UL/CSA Certification:

Personalization

Upgrade to Eurotherm Temp. Controller

KSL-1700X-A1-UL is CE Certified and is ready to pass TUV(UL61010) or CSA certification bench-top high-temperature muffle furnace. The furnace consists of high-quality alumina fiber insulation and 1800 grade MoSi2 heating elements and it's controlled by high precision SCR (Silicon Controlled Rectifier) and temperature controller with +/-1 °C accuracy and 30 programmable segments up to 1700 °C (3092 °F). It is an ideal tool for materials annealing and sintering in your research laboratory. 

SPECIFICATIONS

Furnace construction

  • Double-layer steel structure with air cooling fan to keep the case's temperature below 60°C
  • High purity alumina fiber insulation for max. energy saving
  • 1760 °C (3200 °F) Hi-Purity Alumina Coating inside the chamber for longer service life

Temperature Controller

  • FA-YD518P-AG temperature controller is included.
  • Proportional–integral–derivative control (PID control) and auto-tune function
  • 30 segments programmed with ramping, cooling and dwelling steps
  • Built-in over-temperature alarm and thermocouple failure alarm
  • +/- 1 ºC temperature control accuracy
  • Default DB9 PC communication port
  • Eurotherm 3000 programmable controller with software is optional with +/-0.1 oC accuracy
Temperature controller (optional)

  • MTS02-Y Temperature control software kit (for YD518P series controllers) + 15" laptop package is available at the options bar. Click for detail information about the MTS02-Y software kit. 
  • You may upgrade the temperature controller to the Eurotherm  Controller to achieve 0.1ºC accuracy,  which is fully compatible with LabVIEW. This package includes a Eurotherm 3504 programmer, a communication cable (RS485 - USB) and a software CD. Click the pic left to view the full spec of the Eurotherm 3504 temperature controller.    
Laptop & software (Optional)
    
  • Brand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30 days free trial)  
  • Labview Based Temperature Control System (EQ-MTS01) enables the user to edit temperature profiles, manage heat-treatment recipes, record and plot data for MTI furnaces.

Inside Chamber Size

160mm x 150mm x 150mm (6.3" x 5.9" x 5.9"), 3.6L

France Door Block Dimension

138mm x 138mm (5.4" x 5.4"). Thickness: 60mm

Standard Working Temperature

1600° C or 2912° F  (continuous)

Maximum Working Temperature

1700° C or 3092° F (< 3 hours)

Heating Rate

0 ~20 °C/min (≤10°C/min recommended)

Temperature Accuracy

+/- 1° C


Temperature Uniformity

  • +/- 5°C over 120 mm (5") @ 1700°C 
  • +/- 2°C over 80 mm (3") @ 1700°C

Heating Element

Super 1800 grade MoSi2 Heating Elements (30 x 300 mm) (4 pcs)

Thermocouple

B-Type  (Pt-Rh to Pt-Rh) with Alumina tube 

Working Voltage

AC 208V-240V single phase, 50/60 Hz (35A air breaker required)

Note: Plug is not included, and it is suggested you use NEMA L6-30P plug for AC 208~240V)

 

Max. Power

4 KW 

Outside Size

  515 x 500 x 730 mm (20.28" x 20" x 28.75")

Net Weight

100 Kg (230 lbs)



Warranty

  • One-year limited warranty with lifetime support.  (Consumable parts such as sample plates and heating elements are not covered by the warranty, please order the replacement at related products below.)
  • ATTENTION: Any damages caused by the use of corrosive and acidic gasses are not under the coverage of MTI One Year Limited Warranty.
Compliance
  
  • CE Certified
  • NRTL or CSA certification is available upon request at an extra cost
Shipping Dimensions 48" x 40"x 45"
Shipping Weight  
350 lbs 


Application Notes
  • Warning: MoSi2 heating element is used in the high temperature under the oxidizing atmosphere. It will form the SiO2  film which can keep the element from being melted. During the oxidizing process, the SiOprotecting film is formed again when the element continues to be used. The MoSi2 heating element must not be used in the temperature between 400 °C and 700 °C for long time, otherwise, the element will be cremated under the strong oxidizing function in the low temperature.
  • Please click here to learn how to DIY gas purging system



Installation Demo Video
      

STANDARD PACKAGE

P/N

Description

 Quantity

 Click pic to order extra

KSL-1700X-UL KSL-1700X-UL High-Temperature Muffle Furnace  1 set

KSL7-01

Super 1800 grade MoSi2 Heating Elements (30 x 300mm), 4 pcs installed in furnace

 4 pcs

KSL7-02

B-Type Pt-Rh to Pt-Rh Thermocouples with Alumina Protection Tube

 1 set

KSL7-03

Al2O3 Sample Plate ($95.00/ea)

 1 pcs

KSL7-04

Al2O3 Furnace Door Block ($180.00/ea)

 1 pcs

KSL7-06

Crucible Clip ($25.00/ea)

 1 pair

KSL7-07

Operation Manual

 1 set

 

Related Products

Shopping Cart
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
Mailing Lists
MTI sponsorships:
MTI Sponsors Thermoelectrics Workshop

MTI-UCSD Battery Fabrication Lab

MTI-VISTEC Cylindrical Cell  Pilot Line

MTI Sponsors the Postdoctoral Awards

Upcoming Shows:

242nd ECS Meeting October 9 - 13 Atlanta GA Booth 200

Recent Attended Shows:
2022 MRS Spring Meeting May 8 - 13 Honolulu Hawaii Booth 209

TMS 2022 Feb 27 - March 3 Anaheim CA Booth 509


AABC USA 2021 December 7 - 9 San Diego CA Booth 429


Click here to see our past conferences

 

Notices
1. Prices listed online are valid for the US market and who pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
2. We may add extra charges for paper order and net30 terms due to extra labor costs.
3. The prices listed are subject to change without notice.