Split-able Pouch Cell with Optional Size for Battery R&D - EQ-SPC-Series


Sale Price: Starting at USD$900.00
If you are international, please click this.

Product Options

Max Electrode Dimension:
Material:

EQ-SPC-Series are splittable pouch cells made of Nylon or Peek, which are designed for testing pouch cells with max electrode dimension of different size. Its detachable design allows you to test the pouch cell behavior as well as structural changes of electrode easily, quickly and cost effectively.

Specifications
Design Fearture
  • Easy assembling by only four cap mounting screws
  • Easy to separate after test for microstructure analysis
  • Space saving, compact design allows you put it into the glove box
Material
(Please select at options bar)
    • Nylon or PEEK (Poly Ether Ketone) selectable from product options bar
    • Body: Electrolyte corrosive-proof Nylon which can sustain with temperature up to 80ºC and O-ring: Sealed by electrolyte corrosive-proof PTFE O-rings
    • Body: PEEK (Poly Ether Ketone), which is a semicrystalline thermoplastic with excellent mechanical and chemical resistance properties that are retained to high temperatures and O-ring: Sealed by electrolyte corrosive-proof FKM O-rings
    Appearance EQ-SPC-654519 EQ-SPC-804019 EQ-SPC-955208 EQ-SPC-30529525
    Inside chamber Dimensions

    (Customized size pouch cell are available upon request)
    • 65 mm H x 45mm W x19 mm Thick
    • 80 mm H x 40mm W x 19 mm Thick
    • 95 mm H x 52mm W x 8 mm Thick
    •  
    • 305 mm H x 295.5 mm W x 25.4 mm Thick  
    •    
    Suggested Max. electrode area
    • 60mm H x 40 mm
    • 75 mm H x 35 mm
    • 80mm H x 50mm 
    • 300mm H x 395mm 
    Outside Case Dimensions
    • 89 mm H x 75 mm W x 53 mm Thick
    • 93 mm H x 85 mm W x 55 mm Thick
    • 120mm H x 85 mm W x 40mm Thick
    • 317.5 mm H x 323 mm W x 86 mm Thick  
    Structure
    • One digital pressure gauge installed on top to monitor pressure. You may remove the gauge and use 1/4 female port to inject electrolyte into the pouch cell
    • Two stainless steel contacts to connect anode and cathode by the screw
    • Max. working temperature: 80°C for Nylon, and 120°C for PEEK
    • Max. working pressure: 36psi (0.25MPa) for Nylon and 60psi (0.4Mpa) for PEEK
    Application Note
      • In order to make metal air pouch cell, you can drill holes in the case. We can help you do that at extra cost
      • You may use MTI die cutter to prepare electrode via layer by layer or make winding type pouch cell electrode (click picture below to see the machine)
      • You may need an ultrasonic welder to welding electrode tape to connect to the split cell
                                                                 
                    Die cutter        Ultrasonic Welder           Winding Machine           Pre-coated Electrodes               Other split cells

    Related Products

    Shopping Cart
    Your cart is empty.
    Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
    Mailing Lists
    MTI sponsorships:
    MTI Sponsors Thermoelectrics Workshop

    MTI-UCSD Battery Fabrication Lab

    MTI-VISTEC Cylindrical Cell  Pilot Line

    MTI Sponsors the Postdoctoral Awards

    Upcoming Shows:

    AABC USA 2021 December 7 - 9 San Diego CA Booth 429

    2021 MRS Fall Meeting November 28 - December 3 Boston MA Booth 901

    Recent Attended Shows:
    IMAT Virtual Edition October 26 - 28

    TMS 2020 Feb 23 - 27 San Diego CA Booth 700


    AABC Europe Jan 12 - 16 Wiesbaden Germany


    Click here to see our past conferences

     

    Notices
    1. Prices listed online are valid for the US market and who pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
    2. We may add extra charges for paper order and net30 terms due to extra labor costs.
    3. The prices listed are subject to change without notice.