Home Page
Dual Chamber Glove Box with Gas Purification System (H2O & O2< 1ppm) - VGB-6-II-LD
|
Transported by LTL Freight (Truck)
Product Options
Dual Antechambers: |
|
Pneumatic Door Opener: |
|
|
VGB-6-II-LD is a dual stainless steel glove box designed for researchers in material science, chemistry, semiconductor, and related topics. The purification cylinder is made of BASF antioxidant materials from Germany and UOP water adsorbent materials from the US to achieve a low water and oxygen concentration of lower than 1ppm, so experiments can be conducted in an ultra-clean and highly purified gas environment. It is integrated with a vapor pressure control system, gas purification system, automatic gas regeneration control system, auto alarm, and system data log recording. VGB-6-II is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics. Glovebox with heatable antechamber and refrigerator is optional.
SPECIFICATIONS
Working Voltage |
110VAC or 220VAC, 50/60Hz, Single Phase |
Max. Power Consumption |
1.7KW |
Glovebox Chamber
|
- Fully openable front window panel (tempered glass, 8 mm thick)
- Dimensions: 2400mm(L) x 800mm(W) x 930mm(H)
- Case Material: Stainless Steel 304
- Built-in fluorescent lamp
- Two shelves, 300mm L x 250mm W x 300mm H
- Two pieces of HEPA filters for particle size >0.3 μm
|
Antechambers |
- Large Antechamber Dimensions: 360mm(Dia.) x 600mm(L)
- Small Antechamber Dimensions (for tools): 150mm(Dia.) x 300mm(L)
- Max. vacuum level: 100 Pa
|
Obtainable Purity Level |
- Water concentration: <1 ppm (20°C, 1 atm)
- Oxygen concentration: <1 ppm (20°C, 1 atm)
|
Working Gas |
- Operating gas: Inert gas such as N2, Ar, He
- Regenerating gas: Mixture of H2 (5%) and Operating gas
- Note: If you use Ar gas, please make sure the inside equipment is Ar gas-compatible
|
Gas Purification System |
- Auto regeneration process with user-defined parameters.
- Built-in Regeneration Temperature Controller.
- Automatically purging function is built-in for quickly reducing O2 < 100 ppm & H2O < 100 ppm before cycling.
- The automatic pressure control system is built in to keep the pressure at a constant level.
- Purification Cylinder: made of BASF antioxidant materials (Na86((AlO2)86(SiO2)106.XH20, 5 kg) and UOP water adsorbent materials.
- Moisture removal capacity: 2 kg
- Oxygen removal capacity: 60L
- Stainless steel pipe connection
- Blower: Flow Rate: 90m³/h
|
Filter System (optional) |
- One Organic Solvent Filter System filled with replaceable activated carbon (5.2kg) is optional
- Carbon and solvent vapor filters are available upon request at the extra cost for flammable vapor
|
Pneumatic Door Opener(Optional) |
|
Control system
|
- Siemens PLC control system with 6" touchscreen display
- Water concentration: 0 - 1000 ppm
- Oxygen concentration: 0 - 1000 ppm
- Auto pressure control -5 - 8 mbar
|
Feedthroughs |
- Power feedthrough is included.
- power extension board with 5 outlets, 15A max.
- Can be 110VAC or 220VAC depending on the input source
|
Vacuum Pump
|
- 240L/m Heavy Duty Double Stage Rotary Vane Pump for faster gas exhaust
- Vacuum rate: 7.8 cfm
- Lowest pressure: 0.4pa
|
Gloves |
- Two pairs of NORTH Butyl gloves is included
- Protection against toxic materials
- 8" Dia.x 32" Long
|
Product Dimensions |
3235mm(L) x 1040mm(W) x 1860mm(H) (127" x 41" x 73") |
Heatable Antechamber (optional) |
- The inside door of the antechamber can be opened automatically ( Pic. 1-- Video )
- Heatable Antechamber: 200C max., DN360×600mm (L), available ( Pic. 2-3)
- Refrigerator attachment: -20oC ( Pic.2)
- Two large ante-chambers with central isolating doors are available upon request (Pic. 4 )
Pic. 1 Pic. 2 Pic. 3 Pic. 4
|
Shipping Dimensions & Weight |
2 pallets, 1800 lb total weight #1: 86"x41"x84" #2: 86"x41"x83"
|
Operation Instructions |
|
Warranty & Compliance |
- One Year limited warranty with lifetime support
- Rusting and damage due to improper storage or maintenance are not covered by warranty
- Gloves are consumable items and are not covered under warranty
- NRTL or CSA certification is available upon request at the extra cost
|
Application Notes & Warnings |
- The interconnections between the glovebox chamber and the gas purification system must be unimpeded during the purification cycles.
- Using corrosive gasses is prohibited as they will damage the water and oxygen sensors.
- Regularly perform regeneration to maintain optimum purification efficiency.
- The O2 removal rate is dependent on the type of purging gas used. For a faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass.
- Corrosive liquid, such as LiPF6, must remain sealed in a container inside the glove box.
- The glove box may connect with the tube furnace upon request
- You may order a vacuum transportation jar to deliver the air-sensitive sample into or out of the glovebox.
-
|
|
|
| | |
|
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed. | |
| | |
|
MTI sponsorships: MTI Sponsors Thermoelectrics Workshop
MTI-UCSD Battery Fabrication Lab
MTI Sponsors the Postdoctoral Awards
Upcoming Shows:
|
|