KSL-1200X-L5-UL is a five sides heating muffle furnace, which is designed for annealing super-alloy and precious metal with more uniform temperature zone and SiC sheet is installed on the bottom of the chamber which can load heavy sample up to 100 kg.

SPECIFICATIONS

Structure
                 
  • Five sides heating ( left, right, front, back, and bottom ) to achieve more uniform temperature zone.
  • One SiC sheet is placed on the bottom of the chamber ( top of the heating element ) to support heavy sample load up to 100 kg.
  • Double temperature controller to ensure furnace never overshoot 
  • Thermal efficient ceramic (high purity alumina fiber) insulation surrounding the chamber provides maximum energy efficiency. 
  • Heavy-duty double-layer structure with the cooling fan to keep furnace exteriors safe to touch. 
  • Built-in vent port removes undesirable contaminants and moisture; extends the life span of the heating elements and furnace.
Chamber Dimensions

  • 16 " x 16'' x 16'' (D x H x W) (40x40x40 cm)
  • Capacity:64 liters/ 4100 cubic-inches/ 2.37 cubic ft
Power

  • 8800 Watts
  • Note: Power cable included but without the plug. Please install a plug by your own or click the link left the picture to choose a plug according to your country or your lab requirement
Current Rating
  • 45 A
Voltage
  • AC 208 - 240 Single phase, 50/50Hz
Operating Temp Range 
  • 100-1100°C-Max continuously
  • 1200°C-Max under an hour
  • Note: for using =>1000°C, the furnace block must be placed front chamber.
Stability at 1000oC
  • +/- 1°C
Uniformity at 1000oC
  • +/- 1°C within 250 × 250 × 250mm central zone
  • +/- 1.5°C within 300 × 300 × 300mm central zone
Max. Heating Rate
  • 20°C/ min
Temperature Controller
  • FA-YD518P-AG temperature controller is included.
  • Proportional–integral–derivative control (PID control) and auto-tune function
  • 30 segments programmed with ramping, cooling and dwelling steps
  • Built-in over-temperature alarm and thermocouple failure alarm
  • +/- 1 ºC temperature control accuracy
  • Default DB9 PC communication port
  • MET Certified
Optional +/- 0.1ºC  Controller
 
  • MTS02-Y Temperature control software kit (for YD518P series controllers) + 15" laptop package is available at the options bar. Click for the detail information about the MTS02-Y software kit. 
  • You may upgrade the temperature controller to the Eurotherm Temperature Controller which is fully compatible with LabVIEW and provide +/- 0.1ºC accuracy. This package includes a Eurotherm programmer, a communication cable (RS485 - USB) and a software CD. Click the pic below to view the full spec of the Eurotherm temperature controller.      
Laptop, software & WiFi Control(Optional)
  • Brand new laptop with Microsoft Window 10 and Microsoft Office 2013 (30 days free trial) for immediate use.
  • Labview Based Temperature Control System (EQ-MTS01) enables user to edit temperature profile, manage heat-treatment recipe, record and plot data for MTI furnaces.
  • A wireless remote control provides up to 300 meters operating range.
  • The above features are available upon request at an extra cost (up to $1,000). 
  • Note: The software is only compatible with MTI’s Yudian Temperature Controller
  •     

Optional

1/4'' Barbed 
Gas Inlet/Outlet can be installed on the back of furnace upon customer's request. ($99.95/each)
Overall Dimensions
26" x 28'' x 28 (DxHxW)

Shipping Weight  300 Lbs (shipping by pallet)
Warranty
  • One-year limited warranty with lifetime support.  
  • ATTENTION: Any damages caused by the use of corrosive and acidic gasses are not under the coverage of MTI One Year Limited Warranty.
Compliance
  • CE Certified
  • NRTL (UL61010) or CSA certification is available at extra cost. 
                        

Application Notes
  • This furnace is a vacuum sealed furnace, toxic or explosive materials and gasses are not recommended for use with this furnace without necessary safety controls and supervision. 
  • Small cracks may appear on the surface of the refractory ceramics over extended use. This is a normal occurrence and the cracks may be repaired with alumina coating.
  •  click here to choose a crucible
Operation Instructions                  

Related Products

Shopping Cart
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
Mailing Lists
MTI sponsorships:
MTI Sponsors Thermoelectrics Workshop

MTI-UCSD Battery Fabrication Lab

MTI-VISTEC Cylindrical Cell  Pilot Line

MTI Sponsors the Postdoctoral Awards

Announcement:
MTI KJ Group Files Lawsuit Against Shangdong Gelon LIB Group for Copyright Infringement of MTI products and Manufacture & sale of counterfeit goods 

MTI and Celgard have successfully reached a settlement under court for the litigation on patent and trademark


Upcoming Shows:


Recent Attended Shows:
IMAT Virtual Edition October 26 - 28

TMS 2020 Feb 23 - 27 San Diego CA Booth 700


AABC Europe Jan 12 - 16 Wiesbaden Germany


Click here to see our past conferences

 

Notices
1. Prices listed online are valid for the US market and who pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
2. We may add extra charges for paper order and net30 terms due to extra labor costs.
3. The prices listed are subject to change without notice.