Home Page
Vacuum Planetary Centrifugal Mixer w/ Two Containers (600ml) & Optional Ball Mill Jars - MSK-PCV-300-LD
|
In stock
Item Number: MSKPCV300
Transported by LTL Freight (Truck)
|
The planetary centrifugal vacuum mixer MSK-PCV-300-LD is designed for mixing and deaerating various kinds of liquid, slurry, paste, and powder materials. It could be used for mixing and homogenizing nanopowders, nanotubes, ceramics powders, battery powder/slurry, metal powders, and especially high-viscosity slurry/paste. The vacuum mixing capability is integrated for the best mixing results. The standard package includes two 300 ml containers ( 600 ml total. ~ 1100 g sample ) and counter-weights. High-throughput adapters are also available for 6 samples (7 ml per sample) mixing per batch. Also, you can use the device as an ultra-high-energy ball milling up to 600 G impact force with special alloy jars.
SPECIFICATIONS
Features
|
- Compared with other brands of the planetary centrifugal mixer, MSK-PCV-300 has the following unique features:
- Mixing under vacuum for deaeration
- Dual containers for larger quantities
- Minimized contamination (no metal mixing blade)
- Centrifugal acceleration: 600 G Max.
- Nanopowders, ceramic powders
- Slurry
- Paste
- Mechanical alloying with special alloy jars (optional)
|
Voltage Input |
- Single Phase AC 208 - 240V, 50/60 Hz
|
Power |
- Maximum: 1350 W
- Motor Power: 750 W
|
Mixing
|
- Planetary Centrifugal Vacuum Mixing
- The centrifugal force of rotation and revolution induces convection, homogenizing the materials
- With the vacuum pressure, submicron air bubbles can be efficiently eliminated from the materials
- Max viscosity: 80,000 Pa S
|
Vacuum Capability |
- Pumping Rate: 165 L/min
- Ultimate Vacuum: -95 kPa
- Built-in vacuum pump with integrated control
|
Speed |
- Fixed speed ratio (0.6X between main plate revolution and container rotating)
- Sample Platen Rotation (revolution motion): 600 rpm - 2,000 rpm (adjustable)
- Container Spin (rotation motion): 360 rpm - 1,200 rpm (fixed at 0.6X of the revolution speed)
|
Containers and Counter-Weights |
- Two standard containers and counter-weights are included
- Two 300 ml containers with gas vent, made of high-density Polyethylene (Pic. 1, 2)
- Counter-weights (10, 20, 50 g) with adapter, made of high-density Polyethylene (Pic. 3)
- Pic. 1 Pic.2 Pic. 3
|
Optional containers
|
- Two 100 ml containers (not included) with adapter and gas vent, made of high-density Polyethylene (Pic. 1)
- Two 30 ml containers (not included) with adapter and gas vent, made of high-density Polyethylene (Pic. 2)
- 26 mm Dia. adapter for 30 mL syringe (not included), made of high-density Polyethylene (Pic. 3)
- Two 3-container-sets (10ml) in one adapter are available for high throughput research (6 samples per batch)
- You may also order the special alloy jars for smaller sized ball milling applications (the rightmost pic, click here to see a video)
Pic. 1 Pic. 2 Pic. 3 Pic. 4 Pic. 5 Pic. 6 |
Max. Mixing Volume and Weight |
Container
|
Max Sample Volume
|
Max Sample Weight
|
Max Gross Weight (Container Included)
|
300 mL
|
150 mL
|
140 g
|
300 g ( wet mixing)
|
100 mL
|
50 mL
|
45 g
|
80 g (adapter not included)
|
80 mL(SS)
|
60 mL
|
90 g
|
300 g (adapter included)
|
30 mL
|
15 mL
|
12 g
|
20 g (adapter not included)
|
- Warning: overload may damage the device. Please follow both the volume and weight limit as above when loading the sample.
|
Control Panel Fig.1 Fig.2
|
- Touch screen control panel to program speed and time
- Store up to 6 programs in memory, as shown in Fig.1
- 3 programmable segments, as shown in Fig.2. For example:
- 800 rpm revolution speed (480 rpm rotation speed) for 60 sec;
- 1500 rpm revolution speed (900 rpm rotation speed) for 180 sec;
- 1000 rpm revolution speed (600 rpm rotation speed) for 60 sec.
- The maximum running time for each segment is 200 sec. The maximum total running time is 600 sec
- The rotation direction could be either clockwise (mode A) or counter-clockwise (mode B)
|
Safety and Protection |
- Safety warnings and interlocks are integrated. The unit automatically stops when
- The unit is overloaded with the sample
- The sample is loaded in an unbalanced way
- The top cover is opened
|
Warranty |
- One-year limited standard warranty with lifetime technical support
|
Dimension |
|
Weight |
|
Shipping Weight & Dimensions |
|
Operation Video and Instructions
|
How to mixing How to ball milling |
Application Notes |
- Always use the mixer on a level & stable surface for best performance and maximum safety
- Do not use the mixer in a hazardous atmosphere, or with flammable, explosive, corrosive, poisonous material! Check the chemical resistance of the container with different materials before loading the sample!!!
- Do not overload the mixer! Stop the mixing operation immediately if abnormal sound/vibration is observed
- Use a digital balance to make sure the sample loading is balanced before mixing
- Double-check if the containers are mounted correctly and securely before mixing
- Do not open the cover lid until the rotation has completely stopped! Do not retrieve the containers and/or put a hand close to the mixing fixture while the rotation has not completely stopped!
- Only use the included containers for the mixing operation! Please make sure there is no foreign object in the mixer before mixing
- Please click underline to learn Centrifugal Force calculation
- Please do not use it under Ar gas. Please consider our MSK-PCV-310AR if Ar gas is required
|
|
Sale Price: Starting at USD$3,998.00
|
|
|
|
|
|
|
| | |
|
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed. | |
| | |
|
MTI sponsorships: MTI Sponsors Thermoelectrics Workshop
MTI-UCSD Battery Fabrication Lab
MTI Sponsors the Postdoctoral Awards
Upcoming Shows:
|
|