Browse Categories
Search

High Pressure Oxygen Tube Furnace (HIP) with 20mm ID up to 1100C @ 610PSI - OTF-1200X-HP-55


In stock
Item Number: OTF1200XHP55
4 -6 weeks to delivery for QC

Personalization

OTF-1200X-HP-55 is a split tube furnace with CE/UL/CSA certified electrical components. Ni-based super-alloy tube (55mm O.D x 20 mm I.D x 600 mm L) and flanges/valves. It is designed for use at high pressure (7 MPa) up to 1100°C under oxidizing and inert gas atmosphere to process special compound. It is an ideal furnace to use for preparing new materials under high pressure, and also can be used as mini HIPto treat metallic sample. ( Laptop is included since 9/10/15 ) 

SPECIFICATIONS
Furnace Structure

  • Double-layer steel casing with air cooling.
  • High purity fibrous alumina insulation for max. energy saving.
  • The aluminum heat sink on processing tube to ensure pressure flange and fitting < 80°C
  • All Electric parts are UL certified and ready to pass TUV, CSA, and UL certificate
Power 2.5KW
Voltage AC 208 - 240V Single Phase, 50/60 Hz
Max. Temperature 1100°C
Max. Heating Rate <= 30°C/min

Material and Size of Pressure Vessel



  • Special Ni-based Superalloy: ( Waspaloy or equivalent  )
  • 55 mm O.D x  20 mm  I.D. x 580 mm Length 
  • 1/4BSPP fitting is installed at the end of the flange, and 1/4" high-pressure stainless steel pipe shall be connected to the fitting.
  • Please click the picture below to see the detail of the pressure vessel
           Exterior          Interior
  • Warning: Never put a sample inside tube directly without crucible or isolated foil to avoid sample react with tube alloy.
  • Attention: Processing Tube is a consumable part, you can click the picture below to order replacement or a spare one.     
  • Copper Gasket Size: 27.2mm O.D x 20mm I.D x 2mm thickness
  • The optional torque wrench is available here to avoid overtightening the flange bolts. The suitable tightening torque for 55 ODx 20 ID x 580 L (mm) is the 40-foot pound.
  •     





Compatible Gas and Crucible
                 
Heating Zone length 250 mm  ( single zone )


Temperature Uniformity
  • Constant Temperature Zone length:   50mm within +/-1°C  and  70mm within +/-2°C in
  • Click the picture below to view the details of the Temperature Distribution Curve and Testing:
          http://www.mtixtl.com     Temp. Control ( left meter )
Thermocouple



Omega 3mm OD K Type with high-temperature tolerance (220°C) connector
Temperature Control
  • MET certified 30 programmable segments for precise control of heating rate, cooling rate and dwell time.
  • Built-in PID Auto-Tune function with overheating & broken thermocouple broken protection.
  • Over-temperature protection and alarm allow for operation without attendant(s).
  • +/- 1 ºC temperature accuracy.



PC Control

  • A brand new laptop with pre-installed & tested software included for immediate use.(Laptop is included since 9/10/15) 
  • Pre-installed MTS-02 Control Software is included for controlling and displaying temperature and pressure by PC at a remote location.
  • Please don't try to buy a furnace without a computer because of liability issues   
                   EQ-MTS02-YP Software Download





Pressure Sensor and Display
  • Precision high pressure sensor (Pressure measurement range: 0~25Mpa) installed on pressure vessel.
  • The pressure sensor is installed in the flange. The pressure will be displayed in the pressure controller in the front panel of the furnace.
  • The alarm system is built in the pressure controller which allow the user to set up the high and low limit point of pressure. When the measuring pressure exceeds limit point, the alarm strobe and whistle will be activated for the warning.
  • When the pressure reaches the alarm set point (Max.15Mpa), the pressure inside the vessel will be released via the solenoid valve installed on the flange.                                                                               For Max.pressure >15 Mpa, please shut off the manual needle valve nearby the solenoid valve.
  • Optional: Adjustable High-Pressure Relief Valve 1000 - 10,000 PSI (7 - 70 Mpa), click picture below right to order.
                                  
        Pressure Display(right))          flange assembly             High-pressure  Relief Valve


Pressure Fitting
    • One Super-alloy flange is included.
    • One Aluminum heat radiators are installed in front of the flange to keep flange below 100oC
    • A high-temperature pressure transmitter, MTI-ZQ-GW is pre-installed with flange
    • One solenoid valve(Max.15Mpa) is pre-installed.
    • The safety pressure relief valve is available to be installed at the downstream side. Please click here for details.    


    Optionals
    • You may order four Pt wire ( 0.35 mm dia ) feedthrough to install the furnace for measure material electric conductivity under high pressure up to 1100oC at extra cost.
    • 10 mm Sapphire window can be installed on the flange for Ramman beam under high pressure at extra cost ( click picture below right to see detials)
    • To measure the electric properties of thermoelectric ceramics under high pressure & temperature conditions, please order alumina testing fixture and high-pressure electrical feedthrough (10Mpa Max.) with the furnace (additional fee will apply).
    •  







        Working Pressure vs temperature
    Allowable pressure (SF = 2)
    Heating temperature
    Max. 3046 PSI  (21 Mpa) 800°C
    Max. 1813 PSI  (12.5 Mpa) 900°C
    Max. 914 PSI  (6.3 Mpa) 1000°C
    Max. 610 PSI  (4.2 Mpa) 1100°C
    The allowable pressure is calculated based on Barlow's formula. S = yield strength. Safety factory= 2
    Click to download GH747 nickel-based alloy datasheet
    Warning
    • Please set up a pressure alarm point in digital pressure display before the operation
    • Must install a pressure regulator on the gas cylinder to increase pressure gradually.
        Heating Element     Fe-Cr-Al Alloy doped by Mo


        Dimensions
        550 x 380 x 520mm
         (click to enlarge the picture)
        Net Weight     ~45Kg
        Shipping package Dimensions     45x45x35 inch
        Shipping weight     200lbs
        Warranty     One year limited warranty (Consumable parts such as o-rings and heating elements are not covered by the warranty, please order the replacement at related products below.) 
       


        Certificate
    • CE Certified
    • NRTL or CSA certification is available at the extra cost
               



        Operation Instructions   
                    
        Application Notes     Hytort Application, or named Hydroretorting of Shale Oil is a process developed by IGT to double the yield of shale oil and hydrocarbon gasses. Please click underlined to view research paper.
        Safety Notes

          
    The picture shows Ni-based Superalloy ( Waspaloy or equivalent) processing tube under overpressure test.
    • Ni-based Super-alloy ( Waspaloy or equivalent) is a reliable processing tube which can be used under high temperature and high pressure. It has excellent ductility and tensile property so only creep deformation happens under overpressure destruction test and following by a crack formed (usually at the hot zone at the center of the tube) to release the pressure. Brittle fracture won’t happen in the overpressure destruction test which means no tube explosion will happen under
    • Please never use ordinary SS tube to connect to gas-inlet for using > 5Mp pressure.
    • Attention: For the use with flammable, toxic or corrosive gasses, you must contact MTI engineering group for the consultation to know all the prerequisites and precautionary measures.
    • Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure. Click here to learn the installation of a gas regulator.
    • Do not over-tightening the flange screws as this may cause permanent damages to the flange or screws. Please refer to the instructions about proper torque for installing CF flange bolts. We recommend you use a torque wrench to tighten the screws with the flange.
    • Warning: Never put a sample inside the tube directly without crucible or isolated foil to avoid sample react with tube alloy.

    Related Products

    Shopping Cart
    Your cart is empty.
    Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
    Mailing Lists
    MTI sponsorships:
    MTI Sponsors Thermoelectrics Workshop

    MTI-UCSD Battery Fabrication Lab

    MTI Sponsors the Postdoctoral Awards


    Upcoming Shows:

    2023 MRS Spring Meeting April 11 - 14 San Francisco CA Booth 104

    243rd ECS Meeting May 28 - June 2 Boston MA Booth 231

    AABC Europe 2023 June 19 - 22 Mainz Germany Booth 102

    Recent Attended Shows:
    40th International Battery Seminar Exhibit March 20-23 2023 Orlando FL Booth 121 

    TMS 2023 March 19 - 23 San Diego CA Booth 609 

    Click here to see our past conferences

     
    Notices
    1. Prices listed online are valid for the US market and who pay by credit card only. There will be extra charges for shipping & handling. Prices vary from country to country.
    2. We may add extra charges for paper orders and NET 30 terms due to extra labor costs.
    3. The prices listed are subject to change without notice.