Browse Categories
Search

Splitable Drum Collector ( 450 RPM Max ) with Optional Oscillation Fixture For DIY Electrospinning - MSK-ESDC-3000


Sale Price: Starting at USD$2,398.00
If you are international, please click this.
Transported by LTL Freight (Truck)

Product Options

Type:

MSK-ESDC-3000 is separable 80 mm Dia.x 200 mm L stainless steel drum collector (MSK-DC-3000) and 6-hole oscillation fixture control console (MSK-MD-300) for the nano-fiber electro-spinning DIY system. In this setup, the nano-fibers are winded in the form of an aligned nonwoven membrane on a rotating drum. This method provides a relatively high production rate compared to the plate collector method. The collector and fixture are adjustable freely, and they can be purchased separately.   Selection is available at the top right selection bar, for more information, please contact us.

  • If you use High voltage power in the system, must do Grounding tests(GFCI) before first-time use. Improper grounding may damage the unit.

SPECIFICATIONS

Model (MSK-ESDC-3000) and Features (Combination)
 
  • The combination of MSK-DC-3000 and MSK-MD-300, which is separable.
  • DIY electrospinning system with drum collector and oscillation fixture
  • Manually adjusting space between the drum collector and oscillation fixture
  • 24VDC motor an Ar gas environment compatible
  • Note: MSK-ESDC-3000 can be purchased in one full set, or separately. For more information, please contact us. To built the DIY high voltage electrospinning process, there is more equipment that might need to built-in with. The example can be shown below:
Model
Drum Collector (MSK-DC-3000)

Oscillation Fixture (MSK-MD-300)
Features

  • Drum collector with adjustable rotation speed and digital speed display 
  • Compact, modular design enables DIY flexibility
  • Rotation speed: 100 - 4700 rpm adjustable
  • Speed accuracy: +/- 5 rpm
  • Drum size: 80 mm Dia. x 200 mm L
  • Syringe needle holder to mount up to 6 needles (6 slots of 12 mm Dia. )
  • Two adjustable positions limit sensors to control the fixture movement distance
  • The needle head suggested having 100-200mm distance with collector drum
  • Fixture movement distance: 50 – 270 mm 
Input Power
  • 208 ~ 240 VAC 50/60 Hz, 50 W
  • To use the unit at 110 V, a 100 W small transformer,  can be ordered at MTI at extra cost 
  •     
  • 220 VAC 50/60Hz, 50W
  • To use at 110 V, a 100 W transformer,  can be ordered at MTI at extra cos
  •     
Dimension Size
  • Controller box: 125mm L x 210mm W x 105mm H
  • Collector part: 430mm L x 160mm W x 150mm H
          
  • Controller box: 120 L x 200 W x 85H (mm)
  • Fixture Part: 400L x 120 W x 370 H (mm)
          
Optional (Not Included)
  • To builds a DIY electrospinning system, you may need
    • A high voltage power supply (Click Pic 1 to order)
    • A syringe pump controller to deliver polymer solution (Pic 2 & 3)
    • Ultrasonic spray head (  click Pic.4 to order )
    • An X-Y stage for uniform coating onto a plate collector (Click Pic 5 to order)
    • A fume hood to enclose the system for safety and health (Click Pic 6 to order)
       1         2          3       4 5    6         
Warranty
  • One-year limited warranty with lifetime support.
Shipping Weight
  • 40 lbs
Operation Instruction                          
Application Notes
  • The ability to generate aligned fibers and the degree of alignment depend on the polymer-solvent combination, viscosity, applied voltage, tip-collector distance, and drum rotation speed. User shall  do experiment for best results
  • Use a properly grounded electrical outlet  and away from sources of electromagnetic interference. Improper grounding may cause charge build-up and damage the unit
  • The electrospinning process uses HIGH VOLTAGE! Stay clear of the syringe needle or drum collector during the process to avoid electric shock! Beware of short circuit damage to the unit due to leaking or short distance between charged syringe needle and drum collector
  • Solvents and chemicals used for electrospinning may be poisonous, flammable, oxidizing, or corrosive. It is the user’s responsibility to understand the risks associated with the process and use proper protections. The user is advised to wear protective clothing, mask, goggles, and gloves. The electrospinning process should be confined in an enclosed chamber, such as a fume hood, with proper exhaust handling capability

Related Products

Shopping Cart
Your cart is empty.
Please clear the browsing history before ordering the product. Otherwise, availability and price are not guaranteed.
Mailing Lists
MTI sponsorships:
MTI Sponsors Thermoelectrics Workshop

MTI-UCSD Battery Fabrication Lab


MTI Sponsors the Postdoctoral Awards

Upcoming Shows:
APS March Meeting 2019 March 4-8 Boston MA Booth 312

TMS 2019 March 10-14 San Antonio TX Booth 101

36th International Annual Battery Seminar & Exhibit Mar 25-28 Fort Lauderdale FL Booth 121

Recent Attended Shows:
2018 MRS Fall Meeting Nov 26-29 Boston MA

MS&T 2018 Oct 14-18 Columbus OH


Furnaces North America Oct 8-10 Indianapolis IN


Click here to see our past conferences

 

Notices
1. Prices listed online are valid for US market and whom pay by credit card only. There will be extra charges for shipping & handling. Price various from country to country.
2. We may add extra charges for paper order and net30 terms due to extra labor cost.
3. The prices listed are subject to change without notice.